Spray Cooling Regulating Valve (T942H, T961Y, T962Y Types)
Product Introduction
Spray Cooling Regulating Valve (T942H, T961Y, T962Y Types)
Nominal Diameter: DN20-100
Nominal Pressure: PNl6-420
Operating Temperature: ≤ 600 ℃
Adjustment Range: 10:1~100:1
Adjustment Characteristics: Linear, Equal Percentage
Valve Body Form: Straight Through, Z-shaped, Angular, Cast Or Forged Welded Structure, Flange Or Welded Connection
Execution Mechanism: Electric (linear Or Angular Actuator), Pneumatic, Etc
Standards And Specifications For Spray Cooling Regulating Valves (T942H, T961Y, T962Y Types)
| Manufacturing Standard | Pressure And Temperature Rating | Structural Length | Welding End | Sealing Surface Leakage Test |
| GB10869 ASME B16.34 | JB/T3595 ASME B16.34 | JB/T3595 ASME B16.10 | JB/T3595 ASME B16.25 | GB10869 MSS-SP-61 |
Advantages And Uses Of Spray Cooling Regulating Valves (T942H, T961Y, T962Y Types)
Boiler Superheater, Reheater, Spray Cooling System.
Low Pressure Bypass Spray Cooling System.
Water Supply System And Pressure Regulation For Spray Cooling Of Temperature And Pressure Reducers, Temperature Reducers, Etc.
Adjustment Of Water Supply Flow For Other Large Pressure Differentials And Bypass Systems.
This Valve Can Achieve Small Flow Regulation, With A Wide Range Of Adjustment, Smooth Operation, And Easy Maintenance.
Technical Characteristics Of Spray Cooling Regulating Valves (T942H, T961Y, T962Y Types)
Multi Stage Throttling, Cage Type Throttling Sleeve Matched With Needle Valve Core, Can Withstand Large Pressure Differences.
The Valve Seat Is Individually Compressed And Sealed, With A Conical Sealing Surface For Reliable Sealing. When Combined With An Unbalanced Valve Core, It Can Achieve Zero Leakage.
The Components Inside The Valve Are All Coated With Stainless Steel Surface Coating Technology, Which Is Resistant To Erosion And Has A Long Service Life.
The Single-stage Pressure Difference Is Relatively Reduced, Which Expands The Regulation Range, Especially At Low Flow Rates, And Still Has Good Regulation Performance. The Single-stage Pressure Difference Is Controlled Within The Critical Pressure Difference, And There Is No Occurrence Of Cavitation Or Flash Evaporation.
The Clearance Between The Sleeve And The Valve Core Is Reasonable, Equipped With A Guide Sleeve, With Good Guiding Performance And Smooth Operation.
The Valve Operation Is Flexible, The Adjustment Is Precise, There Is No Vibration, And There Is No Noise.
Main Component Materials Of Spray Cooling Regulating Valves (T942H, T961Y, T962Y Types)
Name | Valve Body And Valve Cover | Valve Seat | Valve Stem (disc) | Gasket | Filler |
Material | 25# | 2Cr13+802 | 2Cr13 Nitriding | Spiral Wound Gasket | Flexible Graphite |