Low Temperature Quick Open Emergency Shut-off Valve

Low Temperature Quick Open Emergency Shut-off Valve

The Low-temperature Emergency Shut-off Valve Is A Safety Valve Specifically Designed For LNG Gasification Stations, Belonging To The Category Of Low-temperature Valves. It Is Produced By Manufacturers Such As Weidun VTON And Shanghai Evers, And Developed Based On Japanese Technology And The Actual Needs Of LNG Gasification Stations In China. This Valve Is Mainly Used In The Transportation System Of Low-temperature Media Such As Liquefied Natural Gas, Liquid Oxygen, And Liquid Nitrogen, And Is Ap
Low profit
Product Full
Fast delivery

Product Introduction


Low Temperature Emergency Shut-off Valve Is Specifically Designed ForLNG Gasification StationThe Safety Valve Belongs To The Category Of Low-temperature Valves, Produced By Manufacturers Such As Weidun VTON And Shanghai Evers, And Developed In Combination With Japanese Technology And The Actual Needs Of Chinese LNG Gasification StationsThis Valve Is Mainly Used ForLiquefied Natural GasTheLiquid OxygenTheLiquid NitrogenTransportation System For Low-temperature Media, Applied To LNG Tanks, Tankers, AndLow Temperature Storage TankWait For The Scene And Execute The Emergency Cut-off Protection Function.

This Product Adopts Cast Stainless Steel Valve Body, CF8/CF8M Material Valve Body And Stainless Steel Valve Stem, And Uses Sealing RingsPTFEOrPCTFEMaterial, Nominal Diameter DN25-DN100, Suitable For Temperatures Ranging From -196 ℃ To+75 ℃. The Opening And Closing Control Is Achieved Through The Compression Spring Of The Cylinder Piston. When The Ambient Temperature Reaches 70-75 ℃, The Melting Plug Automatically Melts And Triggers The Closure. At The Same Time, A Manual Operation Device Is EquippedThe Structure Includes A Dual Sealing System, Fire And Explosion Prevention Design, And Buffering Function. Installation Requires Strict Degreasing Treatment And Avoids Welding Damage To The Sealing Surface

It Plays An Irreplaceable And Important Role In The Safety Of LNG Gasification Stations, Ensuring The Normal Operation Of Various LNG Gasification Stations And Effectively Avoiding Major Safety Accidents Caused By Gas Leakage, Deflation, And Other Reasons.


Product Technical Parameters


Product Name: Low Temperature Pneumatic Emergency Shut-off Valve

Product Specification: Nominal Diameter: DN25~DN100

Applicable Media: Liquid Nitrogen, Liquid Oxygen, Liquid Argon, Liquefied Natural Gas, Liquid Ethylene, Etc. (LNG, LO2, LN2, LAAr)

Material: Valve Body, Handwheel: Cast Stainless SteelCylinderBracket: Cast Aluminum Valve Stem: Stainless Steel

Other: Welding Form: Plug Welding, Can Also Be Welded By Adding Pipes To Form Butt Welding

Caution: Avoid Oil

According To Relevant National Standards, Emergency Shut-off Valves Must Be Installed At LNG Output Ports To Ensure The Safe Operation Of LNG Tanks And Tankers, And To Cut Off Hazardous Sources In Case Of Accidents To Reduce Personnel And Property Losses.

Main Component Materials

Part Name

Valve Body

Valve Disc

Valve Cover

Valve Stem

Handwheel

Main Seal

Material

0Cr18Ni9

0Cr18Ni9

0Cr18Ni9

0Cr18Ni9

HT200

PCTFE

External Connection Dimensions Of Low-temperature Emergency Shut-off Valve(mm) (VDJQ-20~50 And VDJQ32B~50B Models)

Model

H

H1

Do

D1

D

B

W1

W2

M

VDJQ-20P

One Hundred And Eighty-nine

Four Hundred And Seventy-eight

Twenty

Twenty-five Point Five

One Hundred

Eight

Eighty

One Hundred And Thirty

Rc1/4

VDJQ-25P

Two Hundred And Forty

Five Hundred And Thirty

Twenty-five

Thirty-two Point Five

One Hundred

Eight

Ninety

One Hundred And Thirty

Rc1/4

VDJQ-32P

Two Hundred And Fifty

Five Hundred And Forty-one

Thirty-two

Thirty-eight Point Five

One Hundred

Eight

One Hundred And Five

One Hundred And Thirty

Rc1/4

VDJQ-40P

Three Hundred And Six

Six Hundred And Ninety-four

Forty

Forty-five Point Five

One Hundred And Twenty-five

Eight

One Hundred And Twenty

Two Hundred And Seven

Rc1/4

VDJQ-50P

Four Hundred

Eight Hundred And Four

Fifty

Fifty-seven Point Five

One Hundred And Forty

Ten

One Hundred And Forty

Two Hundred And Seven

Rc1/4

VDJQ-32B

Two Hundred And Fifty

Four Hundred And Eighty-nine

Thirty-two

Thirty-eight Point Five

One Hundred

Eight

One Hundred And Five

One Hundred And Thirty

Rc1/4

VDJQ-40B

Two Hundred And Twenty-seven

Five Hundred And Sixty-seven

Forty

Forty-five Point Five

One Hundred And Twenty-five

Eight

One Hundred And Twenty

One Hundred And Sixty

Rc1/4

VDJQ-50B

Two Hundred And Thirty

Five Hundred And Seventy

Fifty

Fifty-seven Point Five

One Hundred And Twenty-five

Ten

One Hundred And Forty

One Hundred And Sixty

Rc1/4

VDJQ65-100 External Dimensions (mm)

Model

H

H1

Do

D1

D

B

W1

W2

M

VDJQ-65P

Two Hundred And Fifty

Six Hundred And Fifty-four

Sixty-five

Sixty-four

One Hundred And Forty

Seven

Two Hundred And Sixteen

Two Hundred And Seven

Rc1/4

VDJQ-80P

Three Hundred And Twenty

Seven Hundred And Seventy-five

Eighty

Eighty-one

Two Hundred

Eight

Two Hundred And Forty-one

Two Hundred And Fifty

Rc1/4

VDJQ-100P

Three Hundred And Twenty

Seven Hundred And Seventy-five

One Hundred

One Hundred

Two Hundred

Nine

Two Hundred And Ninety-two

Two Hundred And Fifty

Rc1/4

Product Working Principle


When The Cylinder Is Filled With The Specified Pressure, The Piston Rises To Drive The Valve Stem To Open The Valve. When It Is Closed, The Gas Inside The Cylinder Is Released. The Piston, Under The Action Of The Spring, Drives The Valve Stem And Valve Disc To Move Downwards. The Sealing Element Presses The Valve Seat Tightly, And The Valve Closes;

When Operated Pneumatically, When The Ambient Temperature Around The Valve Reaches The Melting Temperature Of The Fusible Metal (for Emergency Shut-off Valves Used In Low-temperature Tank Trucks And Low-temperature Tank Containers, The Fusible Plug Should Melt At 75 ℃± 5 ℃), The Fusible Metal Inside The Plug Will Melt, And The Working Pressure Inside The Cylinder Will Be Automatically Discharged. The Piston, Under The Action Of The Spring, Drives The Valve Stem And Valve Disc To Move Downward, And The Sealing Element Presses The Valve Seat Tightly, Causing The Valve To Close;

Rotate The TopHandwheelDrive The Valve Stem And Disc Upwards To Manually Open The Valve.